What was found
CORROSION WAS FOUND ON FLOOR SUPPORT, AT FRAMES 68-69, Y1292, R. REMOVED CORROSION IAW SRM 51-22-00. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS FOUND ON FLOOR SUPPORT, AT FRAMES 68-69, Y1292, R. REMOVED CORROSION IAW SRM 51-22-00. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.