What was found
L1 DOOR WAS DIFFICULT TO ARM. MAINTENANCE FOUND GIRT BAR STUCK. ATTEMPTED TO RE-PIN THE SLIDE AND THE ENTIRE SLIDE FELL OUT, STILL UN-DEPLOYED. R & R DOOR SLIDE AT L-1 IAW AMM 25-65-01. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L1 DOOR WAS DIFFICULT TO ARM. MAINTENANCE FOUND GIRT BAR STUCK. ATTEMPTED TO RE-PIN THE SLIDE AND THE ENTIRE SLIDE FELL OUT, STILL UN-DEPLOYED. R & R DOOR SLIDE AT L-1 IAW AMM 25-65-01. OK FOR SERVICE.