What was found
DURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA STRINGER 42L, ONE INCH FWD OF FRAME 28. REMOVED SURFACE CORROSION. FABRICATED A REPAIR AND INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA STRINGER 42L, ONE INCH FWD OF FRAME 28. REMOVED SURFACE CORROSION. FABRICATED A REPAIR AND INSTALLED.