What was found
L-2 DOOR SILL CORRODED AT FRAME 68, INBD OF GIRT BAR PLATE; REMOVED CORROSION, FOUND BEYOND ALLOWABLE LIMITS. R & R L2 DOOR SILL IAW SRM 53-41-14, FIG 001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L-2 DOOR SILL CORRODED AT FRAME 68, INBD OF GIRT BAR PLATE; REMOVED CORROSION, FOUND BEYOND ALLOWABLE LIMITS. R & R L2 DOOR SILL IAW SRM 53-41-14, FIG 001.