FLT 358, DURING ROUTINE MAINTENANCE CHECK, EMERGENCY LIGHTS TEST WAS PERFORMED. DISPLAY SCREEN SHOWED EPSU BATTERY FAULT. R & R EPSU BATTERY IAW AMM 33-51-38. OPS CHECK PASSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 358, DURING ROUTINE MAINTENANCE CHECK, EMERGENCY LIGHTS TEST WAS PERFORMED. DISPLAY SCREEN SHOWED EPSU BATTERY FAULT. R & R EPSU BATTERY IAW AMM 33-51-38. OPS CHECK PASSED.