What was found
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM Y1292 +2" INBOARD OF L2 DOOR; REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, 51-42-11, 53-00-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM Y1292 +2" INBOARD OF L2 DOOR; REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-72-11, 51-42-11, 53-00-14.