Service difficulty report · Valve · Airbus A320232

Difficulty date
November 21, 2016
Submitted
November 22, 2016
Operation
Air carrier
Aircraft
N599JB
Make and model
Airbus A320232
Aircraft serial
2336
Aircraft time
17,178 hours, 48,418 cycles
Part
Valve
Part number
VFT210B00
Part serial
4566
Condition
Failed
Part time
48,425 hours, 17,178 cycles
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

VENT SKIN VALVE FAULT ON ECAM AT APPROXIMATELY 1500 FT, PERFORMED ECAM PROCEDURE AND QRH AND THEN RECEIVED ECAM FOR BLOWER FAULT CABIN PRESSURE REACHED A MAXIMUM DIFFERENTIAL OF 4.2 PSI. CREW DECIDED TO MAKE AN AIR RETURN TO PBI.; R & R SKIN AIR INLET VALVE PER AMM 21-26-52. R & R CHECK VALVE 2150HM PER AMM 21-26-56 REF LOG PAGE 1873725 ITEM 2 FOR ADDITIONAL WORK ACCOMPLISHED. R & R AVIONIS EQUIP, ENT FILTER PER AMM 21-26-43.