What was found
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM Y512 FASTENER HOLE AFT OF FRAME 66; R & R THE FLOORBEAM IAW SRM 51 42-11, 7 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM Y512 FASTENER HOLE AFT OF FRAME 66; R & R THE FLOORBEAM IAW SRM 51 42-11, 7 51-72-11.