What was found
EMERGENCY LIGHT DID NOT DISPLAY DISARMED MESSAGE WHEN EMERGENCY LIGHT SWITCH WAS SELECTED TO OFF. FOUND THAT PIN 8 ON PO301 CONNECTOR WAS NOT GROUNDED. FOUND PIN H AT GS0287SN GROUND STUD LOOSE. RE-INSERTED PIN H IAW SWPM 20-35-03. EMERGENCY LIGHT MESSAGES NOW OPERATE NORMALLY.