What was found
DURING ROUTINE MAINTENANCE, DISCOVERED THAT EMERGENCY LIGHT IN CEILING PANEL NR 5 WILL NOT ILLUMINATE. R & R EMERGENCY LIGHT POWER SUPPLY NR 2 IAW AMM 33-50-01. OPS CHECKED GOOD. ACFT OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE, DISCOVERED THAT EMERGENCY LIGHT IN CEILING PANEL NR 5 WILL NOT ILLUMINATE. R & R EMERGENCY LIGHT POWER SUPPLY NR 2 IAW AMM 33-50-01. OPS CHECKED GOOD. ACFT OK FOR SERVICE.