What was found
DURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON CROSSBEAM AT FRAME 90, LBL 14. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-12-01, AND SRM 53-23-10. FABRICATED DOUBLER IAW SRM 53-23-10. HEAT TREATED IAW SM NE 40-002. LOCATED, DRILLED DOUBLER IAW SRM 51-41-02. TREATED, PRIMED, AND TOP COATED IAW SRM 51-23-04, 51-23-05, 51-23-06. INSTALLED IAW SRM 53-23-10.