DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOOR STRUCTURE FRAME 65 +18, -Y1732. REMOVED AND REPLACED FLOOR STRUCTURE IAW SRM 51-42-11, AND SRM 53-00-14.