What was found
CORROSION WAS DISCOVERED ON AFT FLOOR STRUCTURE FRAME 66, -Y512. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS DISCOVERED ON AFT FLOOR STRUCTURE FRAME 66, -Y512. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.