Service difficulty report · Proximity Switch · Airbus A320232

Difficulty date
August 17, 2017
Submitted
August 21, 2017
Operation
Air carrier
Aircraft
N639JB
Make and model
Airbus A320232
Aircraft serial
2814
Aircraft time
45,833 hours, 15,961 cycles
Part
Proximity Switch
Condition
Out Of Adjust
Location
R2 Door Slide
Stage of operation
IN
How discovered
V
Nature of condition
P
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

R2 DOOR SLIDE DOES NOT INDICATE ARMED WHEN PRESSURIZED. PERFORMED TSM 52-13-00-810-805-A AND ADJUST PROXIMITY SWITCH 7WN2 IAW AMM 52-71-00-820-002-A , OK. PERFORMED OPERATIONAL TEST TO MEASURE STRUCTURE LEAKAGE IAW AMM 05-53-00-780-003-A01. R2 DOOR SLIDE SHOW INDICATION ON DOOR OXYGEN ECAM PAGE WHEN PRESSURIZED.