What was found
FLT 1674, CHS-JFK. EPSU BATTERY EMER RT FAIL MESSAGE DURING EMERGENCY SYS TEST THRU CIDS. R & R OF THE BATTERY OF THE EPSU AT 12WL IAW AMM 33-51-38. SYS AND OPS CHK GOOD. A/C OK FOR SVC.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 1674, CHS-JFK. EPSU BATTERY EMER RT FAIL MESSAGE DURING EMERGENCY SYS TEST THRU CIDS. R & R OF THE BATTERY OF THE EPSU AT 12WL IAW AMM 33-51-38. SYS AND OPS CHK GOOD. A/C OK FOR SVC.