What was found
FT 1705, MCO-SDQ. HYD G ENG 1 PUMP LO PR. PERFORMED INSP CHECK OF HYD SYS AFT TOTAL HYD LOSS OR ENG PUMP FAILURE OR CAUTION PER AMM 29-00-00. REPLACED GREEN SYS ENG DRIVER PUMP IAW AMM 29-13-51. HP FILTER PER AMM 29-11-45, LP FILTER PER AMM 29-11-44, CASE DRAIN FILTER PER AMM 29-11-43, & HCU FILTER PER AMM 78-31-51. ALL CKS GOOD. NO LEAKS NOTED AT THIS TIME. NO AAI'S FOUND EXTENDED.