What was found
LANDING GEAR WOULD NOT EXTEND. RECYCLED, THEN USED THE MANUAL EXTENSION. DURING GEAR SWING, ON RETRACTION, THE NOSE GEAR DOORS STAYED AMBER. FOUND THE RELAY 62GA TO BE DEAD. R & R THE RELAY 62GA IAW ESPM 20-46-50. OP CHECKED GOOD. FOUND THE NLG DOOR SENSOR 31GA HITTING CFDS. R & R THE SENSOR 31GA IAW AMM 32-31-13. OPS CHECKED GOOD. PERFORMED A FUNCTIONAL CHECK OF NORMAL EXTENSION AND RETRACTION OF THE LANDING GEAR IAW AMM 32-31-00-720-002-A, OPS CHECKED GOOD. ACFT OKAY FOR CONTINUED SERVICE.