What was found
DURING BRIDGE CHECK AT YRQ, FOUND 0.740" LONG CRACK ON THE REF 2 LT WING MAIN BOX LOWER SKIN AT SPAR II & RIB 11. THE CRACK WAS REMOVED AS PER SRM PART II 51-10-03 BUT IS OUTSIDE THE LIMITS OF REF 3 REPAIR. CONTACTED MANFACTURER FOR FURTHER DISPOSITION AND WAS PROVIDED WITH REF 1 ETD. REF 1 ETD PROVIDED APPROVAL TO ACCOMPLISH REF 3 SRM REPAIR WITH A 12 MONTH DTA. EC E18-014-01 ACCOMPLISHED THE TEMPORARY REPAIR AS PER REF 1 ETD WITHOUT DEVIATION. PER REF 5 ALLOWED THE TEMPORARY REPAIR THAT WAS PREVIOUSLY ACCOMPLISHED TO REMAIN AS PERMANENT WITH NO ADDITIONAL INSPECTIONS REQUIRED.