As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FUMES DETECTED & LATER SMOKE IN COCKPIT FORWARD OF GLARESHIELD BETWEEN RIGHT FRONT WINDSCREEN. EMERGENCY DECLARED. LANDED AT SWF. ( WINDSHIELD HEATING SYS ). F/O'S SLIDING WINDOW EXTREMELY HARD OPEN/CLOSE; REMOVED & REPLACED FO'S WINDSHIELD HEATER CONTROL UNIT IAW MM 30-42-01 OPS CHECK GOOD. R/R R/H DIRECT VIEW WINDOW OPS CHECK GOOD REF MM 56-12-00. FOUND POWER TERMINAL ON FO'S WINDSHIELD TERMINAL BLOCK DAMAGED. CRIMPED NEW TERMINAL ON TO WIRE W102-01112-14 AT FO'S WINDSHIELD POWER TERMINAL BLOCK IAW SWPM 20-21-10.