What was found
DURING CURRENT C6 CHECK AT LHT PR DATED 01/18, A GOUGE WAS FOUND ON A PREVIOUS REWORK ON THE LT PYLON SPIGOT FITTING. LHT CONTACTED FOR REPAIR DISPOSITION, WHICH WAS PROVIDED VIA THE REF./3/ MESSAGE, CONSISTING OF SMOOTH BLEND-OUT WITHOUT INCREASING DAMAGE DEPTH, AND PROTECTION, VALID FOR 6 MONTHS SUBJECT TO DTA. LHT ISSUED THE REF./1/ EO ACCOMPLISHING THIS REPAIR DISPOSITION. THE REF./2/ RDAS IS APPROVING THIS REPAIR FOR 6 MONTHS. THIS EC A18-044-01 INCORPORATES THE REF./1/LHT EO WITHOUT DEVIATION FOR TIME LIMITED REPAIR. EC A18-044-02 WILL PROVIDE PLACEHOLDER FOR PERMANENT REPAIR , WITHIN 6 MONTHS, PENDING DTA; THIS REPAIR HAS BEEN APPROVED VIA THE REF./2/ RDAS. THIS REPAIR IS CLASSIFIED AS A MAJOR / CATEGORY "C" TIME LIMITED REPAIR SUBJECT DTA WITHIN 6 MONTHS. THIS REPAIR HAS BEEN APPROVED VIA THE REF./6/ RDAS. THIS REPAIR IS CLASSIFIED AS A MAJOR / CATEGORY "B".