Service difficulty report · Shutoff Valve · Emb ERJ190100IGW

Difficulty date
February 13, 2018
Submitted
February 21, 2018
Operation
Air carrier
Aircraft
N296JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000219
Aircraft time
27,195 hours, 17,438 cycles
Part
Shutoff Valve
Part number
10139521
Part serial
2010100061
Condition
Failed
Location
Engine
Part time
13,797 hours, 9,535 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
G, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DIVERTED DUE TO A OF LOSS OF CABIN PRESSURIZATION AND CABIN OXYGEN MASKS DEPLOYED. BLEED 1 LEAK INFLIGHT, AFTER 2 MINUTES MESSAGE REAPPEARED. COMPLIED WITH QRH. R & R THE HP & PRSOV , FOUND BOTH LEAKING DURING TROUBLESHOOTING. ACCOMPLISHED AN ENG RUN, ACFT OK FOR SERVICE.

More about the Emb ERJ 190-100 IGW