Service difficulty report · Shutoff Valve · Emb ERJ190100IGW

Difficulty date
February 13, 2018
Submitted
February 21, 2018
Operation
Air carrier
Aircraft
N296JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000219
Aircraft time
27,195 hours, 17,438 cycles
Part
Shutoff Valve
Part number
10012463
Part serial
2005100765
Condition
Failed
Location
Nr 1 Engine
Part time
7,356 hours, 5,288 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
G, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DIVERTED DUE TO A LOSS OF CABIN PRESSURE AND CABIN OXYGEN MASKS DEPLOYMENT. BLEED 1 LEAK INFLIGHT, AFTER 2 MINUTES MESSAGE REAPPEARED. COMPLIED WITH QRH. R & R THE HP & NAPRSOV. FOUND BOTH LEAKING DURING TROUBLESHOOTING. RAN ENGINES, OK FOR SERVICE. NR 1 ENG NAPRSOV REMOVED DUE STATIC LEAK WITH APU BLEED AIR SOURCE. REMOVED & REPLACED NAPRSOV IAW AMM 36-11-03 ENG 1. HIGH POWER RUN ACCOMPLISHED, OPS CHECKED OK, NO FAULTS NOTED. NR 1 ENGINE HP VALVE REMOVED DUE STATIC LEAK WITH APU BLEED AIR SOURCE. REMOVED & REPLACED THE NR 1 ENGINE BLEED PRESSURE REGULATING SHUT OFF VALVE IAW AMM 36-11-01 HIGH POWER RUN ACCOMPLISHED. OPS CHECKED OK. NO FAULTS NOTED.