What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT WET L2 DOOR SILL IB Y1732 FR 68 STR 23L AT 3 HOLES. REPAIRED AREA ON L2 DOOR SILL AT HOLE 2 LOCATION FR 67 +22 STR 23L IAW SRM 53-41-14-300-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT WET L2 DOOR SILL IB Y1732 FR 68 STR 23L AT 3 HOLES. REPAIRED AREA ON L2 DOOR SILL AT HOLE 2 LOCATION FR 67 +22 STR 23L IAW SRM 53-41-14-300-001.