What was found
DURING CURRENT (6/2018) C10 HEAVY CHECK AT SAL, UNDERGOING REF /3/ INSPECTION WHEN A CRACK WAS FOUND ON WINDSHIELD LT SIDE POST UPPER SECTION AT FR4 (SEE REF /1/ EA FOT DETAILS). WITHOUT ANY SRM REPAIR OPTIONS, CONTACTED AND PROVIDED REF /4/ REPAIR DRAWING. THIS EC A18-496-01 PROVIDES PERMANENT REPAIR INSTRUCTIONS PER REF /2/ RDAS. EC A18-496-02 TRACKS HFEC INSPECTION AT REWORKED AREA EVERY 4150FC; APPROVED THIS REPAIR PER REF /2/ RDAS AND IS CLASSIFIED AS MAJOR CATEGORY 'B'. REFER TO EC A18-496-01.