DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y765 BTW FR 67 TO FR 69 AFT GALLEY AREA; REPLACED FLOORBEAM -Y765 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261212.