What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y254 BTW FR 12 TO 18 AT FWD GALLEY AREA; REPLACED FLOORBEAM -Y254 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261159.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.