DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RAIL DUMMY -Y 81 AT FR 16 AT FWD GALLEY AREA; REPLACED RAIL DUMMY -Y 81 LOCATED BTW FR 12 TO FR 16 AT FWD GALLEY AREA IAW 51-72-11 AND DWG 53112884. ALL WORK ACCOMPLISHED ON NR 2018- 250242.