What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR STRUCTURE, SEAT TRACK Y765, FR 62 +8.00", STR 23L. CORROSION MEAS. 3.90"L X .772"W X .063" D. MATERIAL LOSS = 29%; CORROSION THAT IS BEYOND ALLOWABLE LIMITS, PER SRM 53-41-15-283-001 ON SEAT TRACK Y765, FR 62, STGR23L. REMOVED AND REPLACED NOTED FLOOR TRACK PER SRM 51-72-11, SRM 51-42-11 AND DWG D53472770.