What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM CORRODED AT FR 68 -Y765; REPLACED FLOOR BEAM AS PER SRM REF 51-72-11 REF HAECO NR 440519-36668.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM CORRODED AT FR 68 -Y765; REPLACED FLOOR BEAM AS PER SRM REF 51-72-11 REF HAECO NR 440519-36668.