What was found
DURING HEAVY MAINTENANCE, HOLE ELONGATED ON CLIP AND ANGLE AT FRAME 63 RIGHT 31 INCHES ABOVE STR 22R (PRIMARY STRUCTURE) (MAJOR REPAIR); REMOVED FABRICADED AND INSTALLED FR63 R/H ST22-26R ATTACH ANGLE AND ATTACH CLIP IAW A320 SRM REF 51-72-11, 51-26-11 REF HAECO NR 440519-36685