What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR STRUCTURE TRACK LEFT LOCATED FR 12-FR 20 AT FWD GALLEY AREA; REPLACED FLOORBEAM TRACK LOCATED AT FR12-20 LT SIDE IN PASSENGER CABIN IAW SRM 51-40-08 AND DRAWING 170-00822-503.