Service difficulty report · Valve · Emb ERJ190100IGW

Difficulty date
August 22, 2019
Submitted
August 26, 2019
Operation
Air carrier
Aircraft
N296JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000219
Aircraft time
31,378 hours, 20,452 cycles
Part
Valve
Part number
10070867
Part serial
2006110620
Condition
Failed
Location
Fan Air
Part time
34,417 hours, 21,797 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 1279, DIVERTED. THE NR 2 BLEED IS CURRENTLY ON MEL, THE NR 1 BLEED FAILED IN ROUTE. BLEED 1 FAIL EICAS MESSAGE IN FLIGHT . RESET SUCCESSFUL. BLEED 1 FAIL MESSAGE HAPPENED AGAIN, RESET SUCCESSFUL. ENGINE BLEED SYS-BOTH-BELOW FL150-APU OK. R & R FAN AIR VALVE IAW AMM 36-11-09. OPS CHECKED GOOD, NO DEFECT NOTED.