What was found
FLT 2137, AFTER TAKEOFF ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH HP VALVE & PRESSURE REGULATING VALVE. PERFORMED A BLEED HEALTH MONITERING CHECK IAW MCC REQUEST. OPS CHECKED GOOD IAW AMM 36-11-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 2137, AFTER TAKEOFF ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH HP VALVE & PRESSURE REGULATING VALVE. PERFORMED A BLEED HEALTH MONITERING CHECK IAW MCC REQUEST. OPS CHECKED GOOD IAW AMM 36-11-00.