What was found
DURING HEAVY MAINTENANCE, INOPERABLE DOOR FRAME EXIT LIGHT RT SIDE AT FWD GALLEY AREA. RESOLVED ON W/O: 1062723 TASKCARD: NR-00012, REF AEROMAN NR W/O 2020-293/1 WCC 2020-277311. REMOVED AND REPLACED EMERGENCY LIGHT POWER UNIT 1, IAW E190 AMM 33-50-01/400, AIPC 33-50-01-01. PERFORMED OPERATIONAL TEST RELATED EMERGENCY-LIGHT POWER UNIT, IAW E190 AMM 33-50-01-710-801-A AND 33-50-00-710-801-A, TEST ARE OK. TOOL USED: MILLIOHMMETER P/N:M1-G-KIT S/N:DC005518. DUE DATE:DEC-03-2020AEROMAN TECH 8605813; RJEY598H QC STAMP 163; RJEY598H.