What was found
FLT 606, FLL-EWR. DOOR LEFT EMERGENCY EXIT AFT OVERWING EXIT INTERMITTENT (ECAM DOOR PG OVERWING EXITS OPEN IND--SLIDE IND ON ECAM OK). ADJUST PROXIMITY SWITCH OF OVERWING AFT LEFT EMERGENCY EXIT DOOR AND PERFORMED OPERATIONAL TEST, IAW AMM 52-71-00, TEST OK AT THIS TIME. MDDR CLEARED, MX-4 UPDATED, PLACARD REMOVED MCC NOTIFIED.