What was found
DURING HEAVY MAINTENANCE, REF N/R 2020-359482 W/O 2020 160/1, INOPERABLE EPSU-EMERGENCY POWER SUPPLY UNIT 11WL IN PASSENGER CABIN. R & R EMERGENCY POWER SUPPLY UNIT EPSU FIN (11WL), IAW AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-A. PERFORMED OPERATIONAL CHECK OF THE EPSU, IAW AMM 33-51-00-710-001-A. TEST IS OK.