DURING HMV, CORROSION ON LT WEB FLOOR STRUCTURE BETWEEN FRAME 87 AND 88 SHEAR PANEL LT WAS REPLACED, PER EMB-190 SRM 51-42-01 PAR 6 FIG 2 AND SRM 51-42-02 FIG 5. ALL WORK ACCOMPLISHED ON TOMX N/R 00279.