What was found
FLT 1493, EWR-STI. DURING DESCENT BELOW 10,000FT UNTIL LANDING INFLIGHT REPORTED STRONG SMELL FROM ROW 10-BACK OF A/C. NO MOISTURE PRESENT. PERFORMED ENGINE RUN WITH THE FLIGHT CREW. ISOLATED BLEED 1 AND 2 AND PACK 1 AND 2, NO ODOR DETECTED DURING ENGINE RUN. THIS IS A LEVEL NR 1 ODOR CONDITION COMPLIED WITH INFORMATION NOTICE 2017-T015F SECTION. A/C OK TO CONTINUE SERVICE.