What was found
"DURING HEAVY MAINTENANCE, CORROSION ON PLATE OF REAR FUSELAGE AT FR 100; UT ON AREA WAS PERFORMED AND FOUND WITH FOLLOWING DIMENSION NOMINAL THICKNESS .063 AND MINIMUM REMAINING THICKNESS .015"" THEREFORE IS OUT OF LIMITS AND WILL BE REPLACED PER EMB -190SRM 51-75-16 PAR 6 PLATE OF REAR FUSELAGE AT FR 100 WAS REPLACED PER EMB -190 SRM 51-41-02,51-42-01, 51-43-01.AND SRM 51-41-01 ALL WORK ACCOMPLISHED UNDER TOMX NR 00524"