As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLT 718, MSP-JFK. ABNORMAL SMELL IN CABIN INSPECTION REQUIRED; ACCOMPLISHED INSPECTION REF 21-00-00-810-801-A. NO FAULTS NOTED AS FLIGHT CRW TURNED PACK 2 OFF. NO ODOR SMELL PRESENT. ACCOMPLISHED THE MAINTENANCE OPERATIONAL TEST OF THE ELECTRONIC EQUIPMENT RACK VENTILATION SYSTEM MAIN COMPONENTS PER AMM TASK 21-28-00/500. VERIFIED VENT SHUT OFF VALVE AND GROUND SHUT OFF VALVE OPERATE NORMALLY