What was found
DURING HEAVY MAINTENANCE, (AFTER IFE RACK REMOVAL) CORROSION FOUND ON SHEARCLIP AT FR 84 BTW STGR 27R AND STGR 28R; (REF TECHOPS MEX WO# 1654 NR# 00506) SHEAR CLIP AT FR 84 BTW STGR 27R AND STGR 28R WAS REPLACED FOR NEW SHEAR CLIP (PN 170-6601-002) PER EMB-190 SRM 51-41-01 PAR 6 FIG 2 SRM 51-41-02 PAR 6 FIG 2 AND SRM 51-43-03 PAR 5 FIG 2