As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION; CORROSION IN SHEAR CLIP AT CF III INTERNAL STRUCTURE LOCATED IN FR 75 BETWEEN STRG 28L/ 29L ; REFERENCE TOMX WO# 1708 NR# 00452 SHEARCLIP AT CF III INTERNAL STRUCTURE LOCATED IN FR 75 BETWEEN STRG 28L -29L WAS REPLACED PER EMB 190 SRM 51-41-01 AND SRM 51-41-02 TOMX MX# 201000259 QC RII # 201532129 LOG SIGN TOMAX REPAR STATION 4TOY762C RII INSP 236812