As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION; CORROSION IN SHEAR CLIP AT CF III INTERNAL STRUCTURE LOCATED IN FR 86 BETWEEN STGR 27L & 28L ; REF; TOMX WO# 1708 NR# 00430 SHEAR CLIP AT CF III INTERNAL STRUCTURE LOCATED IN FR 86 BETWEEN STRG 27L AND 28L WAS REPLACED PER EMB 190 SRM 51-41-02 AND SRM 51-43-01 TOMX MX# 201000259 RII QC# 201532129 LOG SIGN TOMAX REPAR STATION 4TOY762C RII INSP 236812