What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION: (CPCP FINDING RELATED R.C. 53-23-005-0417).CORROSION IN FASTENERS PERIPHERY OF CENTER SEAT TRACK LOCATED @ Y=300 AND BTWN FR 84-85 IN C.F.III PASSENGER CABIN FLOOR STRUCTURE.; SUMMARY: SEAT TRACK LOCATED AT Y=300.0 AND BTWN FR 84-85 WAS REPAIRED PER EMB 190 SRM 53-23-10/REPAIR 54P. NO SPECIFIC OR ADDITIONAL INSPECTIONS ARE NECESSARY. REF. TOMEX WO 1708 NRC 00414 AND JETBLUE NR 00023 FOR PERTINENT DETAILS. LOG SIGN TOMAX REPAIR STATION 4TOY762C RII INSP 236812