What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION CPCP: CORROSION ON FLOOR SUPPORT FR 16 Y=-1150 MM APROX. W1 AREA (UNDER FWD. LAV.) ; SUMMARY: CORROSION ON FLOOR SUPPORT FR 16 Y=-1150MM W1 AREA (UNDER FWD LAV.) WAS REMOVED AND EVALUATED. FOUND TO BE OUT OF LIMITS PER EMB-190 SRM 51-12-01;SRM51-10-03; 51-75-16. FLOOR SUPPORT WAS REPLACED PER EMB 190 SRM 51-43-03. REF. TOMEX WO 1708 NRC 00373 & JETBLUE NR 0021 FOR PERTINENT DETAILS. LOG SIGN TOMAX REPAIR STATION 4TOY762C RII INSP 236812