Service difficulty report · Actuator · Emb ERJ190100IGW

Difficulty date
January 11, 2022
Submitted
January 19, 2022
Operation
Air carrier
Aircraft
N298JB
Make and model
Emb ERJ190100IGW
Aircraft serial
249
Aircraft time
34,352 hours, 22,403 cycles
Part
Actuator
Part number
2159801
Part serial
1168
Condition
Failed
Location
Outflow-Vlv
Part time
38,086 hours, 24,445 cycles
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT # 1126, FLL-RDU(AIR TURN BACK TO FLL). DOOR PAX FWRD OPEN MESSAGE AFTER TAKE OFF . PRESSURIZATION CLIMBED UNTIL WE LEVELED OFF AT 21000. MAXIMUM ALTITUDE DISPLAYED 7300 DIFF PRESS 6. NO OVERWEIGHT LANDING REQUIRED; PER AMM 52-72-20, REPLACED ROLL PIN TO SHAFT ROLLER DETECTOR AND CHECKED ADJUSTMENT TO FWD PAX DOOR CLOSED SENSOR. DOOR INDICATION NOW CHECKS NORMAL PER AMM 52-72-20. SEE LP #3261376-2 FOR OUTFLOW VALVE ACTUATOR REPLACEMENT. SEE LP #3261379-1 FOR CPCS CONTROLLER REPLACEMENT & PRESSURIZATION CHECK. ALL CHECKS NORMAL & A/C OK FOR SERVICE. AS PER TECH SUPPORT ADVISED TO REPLACED CPCS OUTFLOW VALVE. REMOVED AND REPLACED CPCS OUTFLOW VALVE ACTUATOR IAW AMM 21-31-03 OPS CHEK GOOD. REMOVED AND REPLACED CPCS CONTROLLER PER TECH SUPPORT GUIDANCE REF AMM 21-31-01. ALL OPS CHKS OK. CABIN PRESSURIZATION ACCOMPLISHED PER 21-31-00-720-802-A. NO ABNORMALITIES NOTED

More about the Emb ERJ 190-100 IGW