What was found
FLT #275, BDL-SJU (DIVERTED TO JFK). MAJOR FUME EVENT HEAVY IN COCKPIT AND FWD GALLEY; T/S PER INFO NOTICE 2017-T0151 SECTION 13 PER TSM 05-50-00-810-831-A FOUND APU TO BE SOURCE OF ODOR DUE TO KEAK REF LOG PAGE 3228590 ITEM #1 APU PLACED ON MEL ACCOMPLISHED LEVEL DECONTAMINATION PER AMM 21-00-00 615-803 -A REF LOG PAGE 3228889 ITEM #1 AND 2 PERFORMED ENGINE RUNS AMM 71-00-00 NO FURTHER ODOR NOTED OK FOR SERVICE. ACCOMPLISHED LEVEL B DECONTAMINATION STAGE 2 CLEANING PER AMM 21-00-00-615-803-A. NO FURTHER ORDER NOTED. A/C OK FOR CONTINUED SERVICE. COMPLETED LEVEL B DECONTAMINATION OF ENVIRONMENTAL CONTROL SYSTEM (ECS) UP TO SUB TASK 21-00-00-160-081-CD (8) (A) CONTINUED ON LOG PAGE 3228889 ITEM #2 .