Service difficulty report · Pressure Valve · Emb ERJ190100IGW

Difficulty date
February 28, 2022
Submitted
March 4, 2022
Operation
Air carrier
Aircraft
N231JB
Make and model
Emb ERJ190100IGW
Aircraft serial
033
Aircraft time
41,020 hours, 26,487 cycles
Part
Pressure Valve
Condition
False Indication
Stage of operation
CL
How discovered
O
Nature of condition
S
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT # 2030, RSW-JFK(DIVERTED TO MCO). BLEED 2 LEAK; T/S PER FIM 36-11-00-810-837A ODS SYSTEM NORMAL - NO FAULTS. FOUND LEAKS AT #2 ENG PRSOV AND CROSS BLEED DUCTING GOING TO RT BLEED. SECURED CLAMPS- AFTER OPS CKS NORMAL. RAN APU/ ENG 2 BLEED FOR 1 HOUR- NO FAULTS. AIRCRAFT OK FOR SVC.