What was found
DURING HEAVY MAINTENANCE, INITIAL INSPECTION: [CPCP FINDING] CORROSION IN SHEARCLIP AT FR 90 & STGR 29L-29R AT AFT CARGO COMPARTMENT; SUMMARY OF NRC 00166: CORROSION WAS REMOVED ON SHEARCLIP AT FR 90 STGR29L-29R AT AFT CARGO COMPARTMENT AND MEASURE, OT= 0.40" AND MINIMUM RT 0.011" THEREFORE ITS OUT OF LIMITS, SHEARCLIP WAS REPLACED PER EMB 190 SRM 51-41-02, AND SRM 51-43-01, SRM 51-75-16 PAR 4. TABLE 1 AND JETBLUE GMM 8.18.4.1 PAR 13 REV 29. ALL WORK WAS ACCOMPLISHED ON TECHOPSMX NRC# 00166. SHEAR CLIP-CTL III, AL P/N: 170-66324-001. (CLASSIFIED AS A MAJOR REPAIR)