As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE, CRACK INDICATIONS WERE FOUND IN FRAME SEGMENT 1 (I/B AND O/B POSITIONS) AT THE OVERWING EMERGENCY EXIT HATCH (FWD RH EEH DOOR 843) L= 0.236 INCH APPROX; REF: ARM W/O 2022 3/1 N/R 2022-163377 EMP#86101118 CHECKED BY 8603209 PERFORMED REINFORCED DOOR STRUCTURE MODIFICATION OF EMERGENCY DOOR 843 IAW EC NO A320-52-1144.